The cabinets adopt a side-by-side layout. The cold air sent by air conditioner diffuses into the entire room and is sucked in by the IT equipment fans of the cabinet at the same time; the cold air absorbs the heat emitted by the IT equipment in the cabinet and becomes hot air, which is discharged to the rear of the cabinet In the passage between, a "hot aisle" is formed; the hot air is restricted by the closure of the hot aisle and cannot be diffused to the outside. It is all sucked in by the air conditioner. The hot air is cooled again in the air conditioner and sent into the room. And then next cycle.
1. Suitable for large computer room scenarios, single cabinet power supports 1KW-8KW, total power 24KW-100KW, total number of cabinets 6-15
2. Unit modular design, install the top of the back of the cabinet, each unit can be installed independently, and can be connected with adjacent units, easy to disassemble and replace.
3. Centralized cooling of the computer room. The cold air fills the entire computer room and is sucked into the equipment through the IT equipment fan. The hot air that has absorbed heat is discharged from the back of the cabinet to the hot aisle. The top of the hot aisle is equipped with a duct to suck the hot air into the air conditioner. To refrigerate and enter the next cycle
4. The frame and the horizontal bracket of the cabinet are connected with special connection holes to increase the overall stability effect; in addition to strengthening the channel itself, it also needs to function to facilitate expansion; the installation holes on the mounting bracket are arranged in a grid of ≧25mm for universal assembly .
5. The sealed window of the passage is made of glass, which is coordinated and beautiful with the computer room as a whole. The glass used conforms to the GB 15763.2 -2005 "Safety Glass for Construction" standard to prevent the impact of glass shattering on the data room and maintenance personnel.
6. The movable door is designed as a normally closed state, and is equipped with a buffer automatic closing device, and a push-pull handle is set on both sides for flexible opening.
7. The door and the frame are sealed with wool strips, and the tightness is tight, which can effectively prevent the cooling air from flowing out.
8. A password access control is installed on the outside of the movable door frame of the passage, and a button switch is installed on the inside. The wiring channel is reserved in the door frame assembly, which has the functions of hiding and wiring.
9. The opening angle of the skylight can be flexibly adjusted through the environment of the computer room
10. All power distribution, cooling, and business operation surfaces are on the same side, which is convenient for operation and maintenance personnel to maintain
11. Excellent airflow optimization design to avoid mixing of hot and cold airflow, reducing energy consumption costs
12. The mechanical, chemical, and electrical properties of the materials, fasteners, and seals used in the cold aisle unit body conform to China's national standards, communications industry standards, and relevant IEC standards.
13. Surface treatment: degreasing, pickling, phosphating, spraying (colors can be customized)
14. Green and environmental protection, product material and surface spraying have reached the national non-toxic and harmless spraying standard
15. Standardized components, de-engineering, and overall delivery. It can be instantly matched according to business development and quickly expand.
16. Special reservations can be accepted by customers
1. Working temperature: -5℃~55℃
2. Storage temperature: -20℃~+55℃
3. Working relative humidity: not more than 80% (over 30℃)
4. Storage relative humidity: ≤90%~96% (40℃±2℃)
5. Atmospheric pressure: 65~110kpa