Standard Hot Aisle

Standard Hot Aisle

The hot aisle is a solution for the heat dissipation of the server cabinets in the computer room. The hot aisle is composed of the top sunroof module, normally closed double doors, frame installation units, auxiliary installations, etc. The cold aisle is closed to prevent the air-conditioning from leaking to other areas and avoid The air mixture after heat exchange improves the utilization rate of refrigeration, effectively reduces the energy consumption of the computer room and prolongs the service life of the equipment.

Product Detail

Application Cases

Video

Air organization

The cabinet adopts a "back-to-back" layout. The cold air sent by air conditioner diffuses into the entire room and is sucked in by the IT equipment fans of the cabinet at the same time; the cold air absorbs the heat emitted by the IT equipment in the cabinet and becomes hot air and is discharged to the cabinet In the passage between the rear, a "hot aisle" is formed; the hot air is restricted by the closure of the hot aisle and cannot diffuse to the outside. It is all sucked in by the room-level air conditioner. The hot air is cooled again in the air conditioner and then sent into the room. And then next cycle.

Product Features

1.Suitable for large-scale computer room scenarios, single cabinet  power 1KW-10KW, total power 24KW-120KW, total number of cabinets 6-30

2. Unit modular design, installed on the top of the back of the  cabinet, each unit can be installed independently, and can be  connected with the adjacent unit, easy to disassemble and replace.

3. Centralized cooling of the computer room. The cold air fills the  entire computer room and is sucked into the equipment through the IT  equipment fan. The hot air that has absorbed heat is discharged from  the back of the cabinet to the hot aisle. The top of the hot aisle is  equipped with a duct to suck the hot air into the air conditioner. To  refrigerate and enter the next cycle

4. The frame and the horizontal bracket of the cabinet are connected  with special connection holes to increase the overall stability; in  addition to strengthening the channel itself, it also needs to play a  convenient expansion function; arranging the mounting holes on the  mounting bracket in a grid of ≧25mm, universal assembly .

5. The airtight window of the passage is made of glass, which is  coordinated and beautiful with the computer room as a whole. The  glass used conforms to the GB 15763.2-2005 "Safety Glass for  Construction" standard to prevent the impact of glass shattering on  the data room and maintenance personnel. 

6. The movable door is designed as a normally closed state, and is  equipped with a buffer automatic closing device, and a push-pull  handle is set on both sides for flexible opening.

7. The door and the frame are sealed by wool strips, with high  tightness, that can effectively prevent the cooling air from flowing  out.

8. A password access control is installed on the outside of the  movable door frame of the passage, and a button switch is installed  on the inside. The wiring channel is reserved in the door frame  assembly, which has the functions of hiding and wiring.

9. The opening angle of the skylight can be flexibly adjusted through  the environment of the computer room 

10. All power distribution, cooling, and business operation surfaces  are on the same side, which is convenient for maintenance personnel

11. Excellent airflow optimization design to avoid mixing of hot and  cold airflow, reducing energy consumption costs.

12. The mechanical, chemical, and electrical properties of the  materials, fasteners, and seals used in the cold aisle unit body  conform to China's national standards, communications industry  standards and relevant IEC standards.

13. Surface treatment: degreasing, pickling, phosphating, spraying  (colors can be customized)

14. Green and environmental protection, product material and surface  spraying have reached the national non-toxic and harmless spraying  standard

15. Standardized components, de-engineering, and overall delivery. It  can be instantly matched according to business development and  quickly expand.

16. Special reservations can be accepted by customers 

Working environment indicators

1.Working temperature: -5℃~55℃

2.Storage temperature: -20℃~+55℃

3.Working relative humidity: not more than 80% (over 30℃))

4.Storage relative humidity: ≤90%~96% (40℃±2℃)

5.Atmospheric pressure: 65~110kpa 