Optimizes the use of energy in the following order—solar/wind, battery, grid power, and diesel generator—maximizing green energy utilization
Introduces solar and wind power with AI management, achieving low-carbon, energy-saving, and stable operation for communication base stations
Provides different base station energy system solutions tailored to the user’s specific requirements
DC-48V, optional (AC220V, -24V, and -12V)
Product specification | Physical dimension | 900mm(W)×900mm(D)×2200mm(H); IP55 protection |
Installation mode | Fall to the ground | |
Cooling solution | Intelligent temperature control (heat exchange/air conditioning, energy-saving automatic switching refrigeration) | |
AC input | AC input voltage | Single-phase/three-phase 380VAC input (two-way input interlocking) |
Rectifier module | 50A, fully equipped with 400A in the same slot as the photovoltaic module | |
Photovoltaic input | Photovoltaic module capacity | 550Wp*8 blocks;=4.4kw |
Photovoltaic module | 50A(3000W)*2 | |
Wind power | Wind power | 600W~2000W |
Fan control module | 2KW | |
Generator | Diesel generator set | Silent type, fully automatic, AC 380V, 8KW~20KW (optional) |
Energy storage backup | Lithium iron phosphate battery | 100AH, 51.2V; fully equipped with 4 groups, energy storage 20KWH |
Output characteristics | DC output voltage | 432VDC~58VDC (default 535VDC) |
Output configuration | Battery: 4*125A; DC: 63A*4, 32A*4, 16A*6 AC: input 32A*3, lightning protection class C; socket: 2 channels; | |
Monitoring unit system | Signal input | 1-way analog input (battery temperature); 4-way digital dry contact input |
Alarm output | 4 dry contacts | |
Communication Interface | RS485 | |
Storage | Up to 1000 historical alarm records | |
Sensor | Temperature and humidity, smog, access control, water immersion | |
Environment | Operating temperature | -20~+75°C (-40°C can be started) |
Storage temperature | -40℃~+75℃ | |
Working humidity | 5%~95%(no condensation) | |
Altitude | ≤4000m (1800m~4000m, every time the altitude rises by 200m, the temperature will decrease by 1ºC.) |
Note: Specifications are subject to change without prior notice for product improvement. Data Sheet
Suitable for off-grid locations and regions with high electricity costs where station construction is needed.
Can be used in both grid-connected and off-grid scenarios, particularly in areas where grid electricity costs are higher than diesel generator costs.
We're committed to providing prompt, professional support to ensure your energyneeds are always met with the highest levelof service
We're here to answer your questions and provide the energy solutions that best fit your needs.