1. Suitable for large-scale computer room scenarios, single cabinet power support 1KW-8KW, total power 24KW-100KW, total number of cabinets 6-15
2. Unit modular design, installed on the top of the front of the cabinet, each unit can be installed independently, and can be connected with adjacent units, convenient for disassembly, assembly and replacement
3. Centralized cooling of the computer room, the cold air enters the aisle through the electrostatic floor at the bottom of the cold aisle, and the hot air enters the air conditioner through the air return at the top of the computer room
1. The frame and the horizontal bracket of the cabinet are connected with special connection holes to increase the overall stability, in addition to strengthening the channel itself, it also needs to play a convenient expansion function; arranging the mounting holes on the mounting bracket in a grid of ≧25mm, universal assembly .
2. No threshold design, convenient for barrier-free installation of equipment.
3. Each movable skylight can realize firefighting linkage. When a fire signal is received, the skylight will automatically open, and firefighting gas can enter the channel to extinguish the fire.
4. Each channel is equipped with an emergency stop switch, which can be turned on by the emergency button in a physical way to improve safety and reliability
5. The airtight window of the passage is made of glass, which is coordinated and beautiful with the computer room as a whole. The glass used conforms to the GB 15763.2-2005 "Safety Glass for Construction" standard to prevent the impact of glass shattering on the data room and maintenance personnel.
6. The movable door is designed as a normally closed state, and is equipped with a buffer automatic closing device, and a push-pull handle is set on both sides for flexible opening.
7. The door and the frame are sealed by wool strips, with high tightness, that can effectively prevent the cooling air from flowing out.
8. A password access control is installed on the outside of the movable door frame of the passage, and a button switch is installed on the inside. The wiring channel is reserved in the door frame assembly, which has the functions of hiding and wiring.
9. The opening angle of the skylight can be flexibly adjusted through the environment of the computer room
10. All power distribution, cooling, and business operation surfaces are on the same side, which is convenient for maintenance personnel
11. Excellent airflow optimization design to avoid mixing of hot and cold airflow, reducing energy consumption costs
12. The mechanical, chemical, and electrical properties of the materials, fasteners, and seals used in the cold aisle unit body conform to China's national standards, communications industry standards and relevant IEC standards.
13. Surface treatment: degreasing, pickling, phosphating, spraying (colors can be customized)
14. Green and environmental protection, product material and surface spraying have reached the national non-toxic and harmless spraying standard
15. Standardized components, de-engineering, and overall delivery. It can be instantly matched according to business development and quickly expand.
16. Special reservations can be accepted by customers
1. Working temperature: -5℃~55℃
2. Storage temperature: -20℃~+55℃
3. Working relative humidity: not more than 80% (at +30℃))
4. Storage relative humidity: ≤90%~96% (40℃±2℃)
5. Atmospheric pressure: 65~110kpa